My fellow growers!
Since vertical growing in my country is not that populair I descided to ask my questions on this forum, I hope you guys can help me out.
I drawed the room design down, with numbers matching my questions, I hope this is clear enough. I have quite some experience with indoor growing on dirt, but want to make a switch to hydro. I love the way NFT works so I descided to start working with that. I am able to read the plants through EC and Ph so I think I will be fine. Also I would love to do a vertical grow for a change, simply because no one is doing it over here and 1gr/w is considered the standard of a good grow, I would love to see how I can do better than that.
I will be running with 99 plants and 4 HPS lights (probably 4x600w) in cooltubes. Available room size is 2m X 2m (6.5 ft x 6.5 ft). Will not be using Co2.
Here are my questions matching the drawing (I know in my drawing the upper channel is a bit high, that will be at normal height in the real room):
1) I currently have a 150 liter (39 Gallon) watertank available. Is this a proper size for the amount of plants?
2) I am thinking of running 4 tubes (or more if neccesairy, depending on the size of the outlet extractor) to the fan(s) in the center to bring in fresh air passively. Will this do the trick and give the plants enough fresh air circulation?
3) What size of outlet extractor will be needed here? Normally I take 1m3 for every watt I have on lights, so that will be around 2400m3 (7874 cubic foot). Since I will be using cooltubes will I probably have less temperature problems so I can probably take a smaller one, but I would love to have a little overcapacity so I dont have to run it at 100% and make unneccesairy noise.
4) I am thinking of placing to fans on the floor blowing air up, hitting the plants before hitting the outlet extractor. Thoughts on this? Is 2 a overkill? I see a lot of vertical growers still using clipfans from the top, my opinion is to always take cold air from the bottom and remove hot air from the top.
5) Is my NFT drain good to go the way I drawed it? So all stacked in line?
6) My NFT pipes have a total lenght of 6.5m (21.3 ft) holding around 25 plants per channel. Is a drop of 3% enough? So every meter I drop 3 cm. Total drop on the 6.5m is 19.5 cm (0.6 ft or 7.6 inch)
7) Can I run my cooltubes this way? So connected to the main exctractor? Or would I need a separate extractor for the cooltubes? I could imagine that the extractor will not be happy with the hot air, since the air is also cooling its motor. For that reason I always thought its better to push air through the cooltubes instead of sucking it through them. In that case, what size of extractor would I need to have optimal cooling in both double lighted cooltube channels?
8 ) What is the optimal distance between each netpot hole for our crops? Will probably be growing indicas SOG.
9) How much light can I run in the cooltubes? I often hear 600w is the max for a cooltube. is 4x750w an option?
10) I know its probably hard to give exact numbers on this, but in what rance of L/h or G/h waterpump do I have to look to have optimal water flow? Maybe anyone with a similair system can give me some ideas? I know it depends on the height the pump can lift the water, but I still see lots of difference in the numbers between different pumps matching the height.
11) I forgot my question I had while drawing, probaly smoked to much
I know its a lot off questions, but thanks in advance guys!
Since vertical growing in my country is not that populair I descided to ask my questions on this forum, I hope you guys can help me out.
I drawed the room design down, with numbers matching my questions, I hope this is clear enough. I have quite some experience with indoor growing on dirt, but want to make a switch to hydro. I love the way NFT works so I descided to start working with that. I am able to read the plants through EC and Ph so I think I will be fine. Also I would love to do a vertical grow for a change, simply because no one is doing it over here and 1gr/w is considered the standard of a good grow, I would love to see how I can do better than that.
I will be running with 99 plants and 4 HPS lights (probably 4x600w) in cooltubes. Available room size is 2m X 2m (6.5 ft x 6.5 ft). Will not be using Co2.
Here are my questions matching the drawing (I know in my drawing the upper channel is a bit high, that will be at normal height in the real room):
1) I currently have a 150 liter (39 Gallon) watertank available. Is this a proper size for the amount of plants?
2) I am thinking of running 4 tubes (or more if neccesairy, depending on the size of the outlet extractor) to the fan(s) in the center to bring in fresh air passively. Will this do the trick and give the plants enough fresh air circulation?
3) What size of outlet extractor will be needed here? Normally I take 1m3 for every watt I have on lights, so that will be around 2400m3 (7874 cubic foot). Since I will be using cooltubes will I probably have less temperature problems so I can probably take a smaller one, but I would love to have a little overcapacity so I dont have to run it at 100% and make unneccesairy noise.
4) I am thinking of placing to fans on the floor blowing air up, hitting the plants before hitting the outlet extractor. Thoughts on this? Is 2 a overkill? I see a lot of vertical growers still using clipfans from the top, my opinion is to always take cold air from the bottom and remove hot air from the top.
5) Is my NFT drain good to go the way I drawed it? So all stacked in line?
6) My NFT pipes have a total lenght of 6.5m (21.3 ft) holding around 25 plants per channel. Is a drop of 3% enough? So every meter I drop 3 cm. Total drop on the 6.5m is 19.5 cm (0.6 ft or 7.6 inch)
7) Can I run my cooltubes this way? So connected to the main exctractor? Or would I need a separate extractor for the cooltubes? I could imagine that the extractor will not be happy with the hot air, since the air is also cooling its motor. For that reason I always thought its better to push air through the cooltubes instead of sucking it through them. In that case, what size of extractor would I need to have optimal cooling in both double lighted cooltube channels?
8 ) What is the optimal distance between each netpot hole for our crops? Will probably be growing indicas SOG.
9) How much light can I run in the cooltubes? I often hear 600w is the max for a cooltube. is 4x750w an option?
10) I know its probably hard to give exact numbers on this, but in what rance of L/h or G/h waterpump do I have to look to have optimal water flow? Maybe anyone with a similair system can give me some ideas? I know it depends on the height the pump can lift the water, but I still see lots of difference in the numbers between different pumps matching the height.
11) I forgot my question I had while drawing, probaly smoked to much
I know its a lot off questions, but thanks in advance guys!