So are you aiming to cover a 4'X8' or 32 ft²? If so,
Where I live is hot all year round. I cannot deal with heat that well without spending a lot on ventilation. Don't HPS have this as a con, the excessive heat?
Since heat is an issue, the efficiency (and efficacy) may affect your grow more than the direct electrical savings of the lamp. To compare heat in your 4'X8':
----------------------------------------------------------
2X 1000W HPS DE bare, 40.8% efficient =
960 PPFD
1184W of heat
-----------------------------------------------------------
4xVero29 x 10 bars
10 x HLG-185H-C1400B x 43.90 euro = 439 + 45.07 shipping
40 x Vero29 x 24.79 euro = 991.60 + 112.67 shipping
1588.34
4xVero29 x 50.96 Dissp.W@1.4A@43.03% = 21.93 PARW x 4 = 87.71 PARW/bar
1230 PPFD
1163W of heat
----------------------------------------------------------
4xCXB3070 AD x 10 bars
10 x HLG-185H-C1400B x 43.90 euro = 439 + 45.07 shipping
40 x CXB3070 AD x 32.87 euro = 1314.80 + 112.67 shipping
1977.87
4xCXB3070 AD x 49.83 Dissp.W@1.4A@48.02% = 23.92 PARW x 4 = 95.71 PARW/bar
1346 PPFD
1040W of heat
---------------------------------------------------------
4xCXB3590 CD x 10 bars
10 x HLG-185H-C1400B x 43.90 euro = 439 + 45.07 shipping
40 x CXB3590 CD x 41.87 euro = 1674.80 + 112.67 shipping
2271.54
4xCXB3590 CD x 49 Dissp.W@1.4A@56.2% = 27.54 PARW x 4 = 110.15 PARW/bar
1712 PPFD
876W of heat
-------------------------------------------------------------
In this example all the COB setups are very high intensity, maybe too high for a 4'X8'. So if you cut the number of CXB3590s in half to 980W, you get:
856PPFD
438W of heat
So that is equal intensity/efficacy as the 2000W of HPS but
one third the heat.