I have a Sauder computer work station that I'm converting into a two-level cab. I replaced the flimsy cardboard back with plywood and painted the inside flat white. The temperature in its designated location is pretty cold in the winter and pretty hot in the summer. My budget is very limited so right now I'm leaning towards a hydro grow using CFLs. The reason for the two levels is to have the lower section set aside for vegging and cuttings and the upper section for flowering. An Aerogarden and a seed starter tray should fit down there nicely. Another reason for the two sections is because I'd like to be able to easily convert to an aquapoinc set up sometime down the road.
Since I'm working with 25 cubic feet, I plan on a passive ventilation system with an intake in the lower right made from a filtered residential heat register. I left two shelves in place.. (the top one slides out and the lower one does not) ..Using a section of pegboard as a template, I'll perforate the top shelf with a drill. To perforate the lower shelf.. (and to prevent light bleeding through) ..I'll stagger the placement of the holes by pulling the top shelf out a half inch. I'll then use the top shelf as a template for the lower shelf. Between the two shelves will be two one way furnace filters. The space that is the outer edge of the two shelves will be filled with a length of 2 1/4" x 2 1/4" Frost King A/C weather seal. One concern of mine is how big/small of a fan am I going to need to draw air through this cab.. (suggestions welcome) ..I had a similar cabinet set up back in the late 90s and I used a 9 inch fan mounted on top of the box. Based on my experience then, a 9 inch fan is a bit much.
As I mentioned before, I'm doing this on a very limited budget. I already have a handful of the proper CFLs for vegging. I'm currently leaning in the direction of a 250 watt 2700k CFL for the top section. Particularly this one. Or, I could always go with a 2 foot 4 bulb T5 with supplemental CFLs to help out.
So that's it for now. I'm looking for input on fan size and and lighting set ups. Any and all suggestions are greatly appreciated.
Attached are a few photos of the cab. Dimensions of the upper portion are 2' 4" wide x 2' 9" high x 1' 10" deep. The lower is 2' 4" wide x 1' 11" high x 1' 10" deep.
Thanks!
(Edit: I also intend on a ScrOG in the top section)
Since I'm working with 25 cubic feet, I plan on a passive ventilation system with an intake in the lower right made from a filtered residential heat register. I left two shelves in place.. (the top one slides out and the lower one does not) ..Using a section of pegboard as a template, I'll perforate the top shelf with a drill. To perforate the lower shelf.. (and to prevent light bleeding through) ..I'll stagger the placement of the holes by pulling the top shelf out a half inch. I'll then use the top shelf as a template for the lower shelf. Between the two shelves will be two one way furnace filters. The space that is the outer edge of the two shelves will be filled with a length of 2 1/4" x 2 1/4" Frost King A/C weather seal. One concern of mine is how big/small of a fan am I going to need to draw air through this cab.. (suggestions welcome) ..I had a similar cabinet set up back in the late 90s and I used a 9 inch fan mounted on top of the box. Based on my experience then, a 9 inch fan is a bit much.
As I mentioned before, I'm doing this on a very limited budget. I already have a handful of the proper CFLs for vegging. I'm currently leaning in the direction of a 250 watt 2700k CFL for the top section. Particularly this one. Or, I could always go with a 2 foot 4 bulb T5 with supplemental CFLs to help out.
So that's it for now. I'm looking for input on fan size and and lighting set ups. Any and all suggestions are greatly appreciated.
Attached are a few photos of the cab. Dimensions of the upper portion are 2' 4" wide x 2' 9" high x 1' 10" deep. The lower is 2' 4" wide x 1' 11" high x 1' 10" deep.
Thanks!
(Edit: I also intend on a ScrOG in the top section)