@CobKit , do you think i can put 180 CLU0 48-1212-C4-303M2K1 on a
HLG-600H-30 or a
HLG-600H-36?
(it would nice if anyone can show a spreadsheet of the CLU0 48-1212-C4-303M2K1 down to the minimum Ampere,i cant run it on my Pc.)
if the cob need at ~0.110 Ampere max. 30 volt it would go on the HLG-600H-30 at ~100% load,
if not it should go on the HLG-600H-36,but this have only 16,7 A so the load would be ~80%,ca. 500 Watt.
the efficiency of these drivers doesnt matter 80% or 100% load,is nearly the same and very high,95% up to 95,5%.
first driver would give ca. 600 watt at ~110mA,second driver just only 500 Watt but a little more efficient cobs at 90mA.
can get a package of these cobs very cheap,but the minimum order is 180...and so i dream a little of passive cooling and going very efficience with low driving.
but the voltage go insane high ,is this about all possible to connect?