CabinetBuds
Active Member
Looks Awesome man!!
Thanks CB!! BTW congrats on your harvest man! I hope you are enjoying the fruits of your labors!Looks Awesome man!!
Final goal is to get the ventilation right. I put it all together (I'll show you in a bit) but I'm already gonna change it up. The finished product gave me another better idea so I'll switch it up in a bit. The issue is I was exhausting my cool tubes and AC unit into the wall which leads to underneath the staircase and then exhaust the cabinets to the outside garage vent (opposite wall). The AC unit blows a huge amount of pressure and the cool tubes run a close 2nd and they both throw off the most heat which goes directly into the house. I'll now vent AC and cool tubes to the outside (I now have enough 4" PVC) and the cabinet under the stairs. Makes it better for odor control too!! The only reason I did it this way was basically "instant gratification". I didn't have enough 4" PVC to make the run across the garage and I wanted to dump the AC and cool tube somewhere else. Now's the best time to fix this!great to hear the great progress!! and i read the bugs have not returned on the other thread, so aside from exhausting the heat from the AC, your about done building arent ya? do you have any projects you'd like to do with the cabinet, like wish list shit? keep us posted.
http://www.plantlightinghydroponics.com/grow-light-ballast-kits-c-357.html -- the MH and HPS kits near the bottom of the page.Hey man where did you get thoes hps ballast and the bulbs?? It looks great btw good job!
You are right, it does look like a mess but I think it's because it's spread across 4 different pics. The point behind the design was to minimize 90* bends and stick with 45* or better straight. PVC is perfectly smooth so it's static pressure coefficient is 1 (where flexible ducting has a coefficient of .5 - .7 due to the accordion shape of the inside surface). Static pressure is the force of air measured against the surface, either with air in motion or rest, for which the fan must overcome in order to keep air moving at it's rated cfm.looks real good, a mess from my stand point!! but i am sure the setup is great to give you exactly the right ventilation control!!
Me too. Yours look way more fun than mine. I'm just gluing PVC to trick my Outdoor plant Theresa.sounds like a lot of fun, wish i could help you out!!
sounds like a lot of fun, wish i could help you out!!
Hey I know you guys are here in spirit!Me too. Yours look way more fun than mine. I'm just gluing PVC to trick my Outdoor plant Theresa.
Daniels
The third cab will still have a 400w bulb which will have to be exhausted. The way it's set up right now, it won't be that hard to add in. In fact I was just thinking I'll just bite the bullet and finish all 3 chambers so I don't have to move the cab anymore, because it's heavy!awesome work gamber. shoot, as cool as the top 2 chambers will be from the AC, you probably wont have to cool the bottom cab. but to continue your airflow for all intake and exhaust, you will probably run it inline as well so it pulls and dumps from the same places as the higher cabs, huh??
Coffee Break!Looking forward to more, and bud porn is one step closer!
Coffee Break!
Any guesses?
How much Coffee did you drink?I'm baaaaaacccccckkkkk!