banditos701
Well-Known Member
Hey fellow growers, i am currently setting up a room like below. I have done as much research up to now although im struggling with calculating static pressure, passive intake sizes & deciding on what inline centrifugal extractor to get. I am also not sure what type of fan & filter i should use for Window ( A ) to block anything foreign coming in the room.
I hope i havent asked too many questions already..
I am hoping to run the room with no ac as for now but i am willing to get the required extractors to keep the 3x3 cabinet well ventilated. I also plan to run some co2 if
i manage the get the light cool enough to leave the cabs main exhaust vent off while the ladies use up the co2.
I am building the cab ( left ) with the dimensions of 3 x 3 and i was wondering if 6 Ft would be good for height ? or should i go less for scrog ?
The Cab on the right is already made, all i need to do is add the fluoro's & another pc fan which should hopefully work out?
Main Cab :
Using a Super sun 2 Reflector
600watt Electronic ballast
Inline fan Suggestions :
http://www.xpelair.co.uk/xid150.html
View attachment 2563297
Its rated at 0.17 m3/s at 0 Pa. 0.17 m3/s = 612 m3/h x 0.588 = 360 CFM.
6" Diameter
At 100Pa it is rated at 255 CFM.
At 200Pa it is rated at 150 CFM.
At 300Pa it is rated at 72 CFM.
TD Inline
View attachment 2563298
View attachment 2563299
I will post more inline extractors once i get some sleep. Will really appreciate any help.
Thank You everyone.
Peace
I hope i havent asked too many questions already..
I am hoping to run the room with no ac as for now but i am willing to get the required extractors to keep the 3x3 cabinet well ventilated. I also plan to run some co2 if
i manage the get the light cool enough to leave the cabs main exhaust vent off while the ladies use up the co2.
I am building the cab ( left ) with the dimensions of 3 x 3 and i was wondering if 6 Ft would be good for height ? or should i go less for scrog ?
The Cab on the right is already made, all i need to do is add the fluoro's & another pc fan which should hopefully work out?
Main Cab :
Using a Super sun 2 Reflector
600watt Electronic ballast
Inline fan Suggestions :
http://www.xpelair.co.uk/xid150.html
View attachment 2563297
Its rated at 0.17 m3/s at 0 Pa. 0.17 m3/s = 612 m3/h x 0.588 = 360 CFM.
6" Diameter
At 100Pa it is rated at 255 CFM.
At 200Pa it is rated at 150 CFM.
At 300Pa it is rated at 72 CFM.
TD Inline
View attachment 2563298
View attachment 2563299
I will post more inline extractors once i get some sleep. Will really appreciate any help.
Thank You everyone.
Peace
Attachments
-
20.4 KB Views: 4