Damn ..........Now I am intrigued! well will see then.....wattage bump?HaHiya P!
Don't mean to appear vague on this but I really can't say much on this one and I'm not even privy to all the details. I will say that your hypothesis is not the approach they are taking. Once I'm given the green light, RIU will be the first place I share it with since the implications to the commercial grower are enormous.
C'mon ol buddy...we're talking supplement here...anyone can increase watts...this is about optimizing DLI...it'll be worth the wait...on this you'll have to trust meDamn ..........Now I am intrigued! well will see then.....wattage bump?Ha
Hey Scar!Pics of my Riant 400 w ballast
This thing reaks of cosmoline, like a surplus AK47.
View attachment 2542814
Pic of the case for scale
View attachment 2542815
Unlike what we've seen in the emerging trends with supplemental greenhouse lighting systems whereby 1000 watt DE HPS (Philips) lamps are being specified to work in conjunction with multiple rows of horizontal LED strips (Lumi-Gro), Inda-Gro took a different approach and saw the benefits of bringing the lights closer to the plants, to reduce to the number of hours the plants might need supplemental lighting to achieve optimum levels of crop DLI and by incorporating a proprietary vertical trolley systems and controls design that reduces shadowing effects by the lamps, meets crop DLI, is energy efficient, long life, low heat and enables the commercial greenhouse gardener to manage the photoperiod and Pfr functions from a single fixture.
The VDH process benefits traditional vertical walled trellis systems or may be better suited for vertical gardens whereby the vertical garden trellis system is built in an A frame construction to match the inversely proportional geometry of the VDH frame construction. This will allow optimum DLI values be met first by the sun followed by the with the ability to consistently manage the supplemental lighting systems by maintaining parallel geometry throughout the vertical light rail process. A single local area sensor mounted on the top of the junction box will control both lamps 50-100% light output with the commensurate savings in connected load. A high/low uMol settings switch allows the local area sensors operational sensitivity to be set for thresholds of:
High Setting: 300 to 600 uMol/m2-s (Full bright if < 300, dimmed to 50% output if > 600)
Low Setting: 200 to 400 uMol/m2-s (Full bright if < 200, dimmed to 50% output if > 400)
The VDH system comes wired and nearly completely assembled with the end user required to put in 4 bolts to install the top systems bracket. The VDH will run on any 50/60Hz system that supplies between 120-277v AC. With a 10 year warranty on lamps and drivers, weighing in at 40 lbs and allowing instant on/off as well as step dimming controls this may help to make a difference in how the world see's supplemental greenhouse design going forward.
The sun emits photon packs vertically where once they hit the ionosphere they are distributed in horizontal packets. I'm not a big fan of straight vertical since the plant leaf absorbs light on the tops of the leaf and so much light is lost over the tops of the fan leaves or worse damages the underside of the leaves from that intensity. I like the angled approach that the VDH design incorporates for that reason. That being said 360 is not a problem but controlling the light to put it where you want it is paramount. If you surround the lamp with all plants great but if you're running an aisle you just lost all that energy to the aisle.The 10 yr warrenty is awsome.
That's cool, but I was hoping for a acrylic cool tube version for 360 output with fan provisions..Hint hint
That's what I've been waiting to see, PSU!^^^^ oh you are a sly one Chaz Remove the reflector and gain at least 35% light output/efficiency, always wondered if you could run induction vertically! Running bare bulb is the best way IMO........
Yeah me too!!........But it looks like Chaz is right ^^^ air circulation would lower the bulb temp and decrease light output/ efficiency. Hid bulbs also suffer from this when used in a cool tube supposedly(according to Gavita).That's what I've been waiting to see, PSU!
hey there Scar!Pics of the lil ladys under My Riant grow light.
View attachment 2551459
C99 x Amnesia haze auto2 weeks flower
89 Nl5/HazeC x Bannana platinum og 3 weeks flower
Nevil haze 21 x Mullimbimby Madness
Almost pure sativa 16+ week finnisher.