Hey guys, been in the process of designing my next (and hopefully steady) grow.
I've done a few decent scaled grows but they've fucked up one way or another. I do have extensive knowledge as I spend hours a day reading and have seen many a grow rooms that's run like they should.
What I want for myself is this tent :
http://www.greners.com/secret-jardin-dark-room-grow-tent-dr300.html?___store=english
It's just about 10x10x6.5, which I believe to be plenty for 2 4' x 8' flood tables. Give you a 2' walkway in the middle to do watering/pruning/spraying.
Each table will have 12 plants in 5 gallon smart pots. 6 plants per 1000w vegged until they have a nice and full canopy.
4 1000's (cant decide between the magnum xxxl's, radiants, or sunsystem 2 reflectors, any input?).
This tent will be a closed environment (sealed) so I could run a 4 burner co2 generator to keep co2 levels at 1500 ppm for flowering. Are grow tents capable of keeping co2 contained efficiently if all zippers are closed?
Each table will have 1 8" inline fan pulling air from outside the tent, through 2 hoods, and exhausting it outdoors. This way I can vent most of the heat generated from the lights without wasting precious co2.
I'm going to be using a portable AC as well as a dehumidifier in the tent. This is were most of my worry lies.
http://www.heartlandamerica.com/browse/item.asp?PIN=99721&SC=WIF10001&
Will this unit (10000btu portable ac / 60 pint per day dehuey) handle the grow tent?
I need to know from somebody whose experienced in using portable ac's to cool multiple lights if a unit like this will be enough to keep temperatures between 78-85 with 4 lights as well as a co2 generator running inside the tent.
I've always aircooled my lights, but they still produce plenty of heat which quickly builds up in a sealed environment. Is a 10k btu ac enough to deal with it?
I'm also curious about the dehuey. It claims 60 pints per day, is this enough for a sealed room in the heart of the flowering cycle? There's gonna be a lot of water in these pots, a lot of air movement too but I realize it can get pretty humid in there. Will I need to buy a more expensive dehumidifier to keep up?
Not really relevant but there will also be a Phresh filter (12") scrubbing constantly either inside the tent or in the room the tent shall be in.
Thanks for the read as well as any feedback you may give, smoke on
I've done a few decent scaled grows but they've fucked up one way or another. I do have extensive knowledge as I spend hours a day reading and have seen many a grow rooms that's run like they should.
What I want for myself is this tent :
http://www.greners.com/secret-jardin-dark-room-grow-tent-dr300.html?___store=english
It's just about 10x10x6.5, which I believe to be plenty for 2 4' x 8' flood tables. Give you a 2' walkway in the middle to do watering/pruning/spraying.
Each table will have 12 plants in 5 gallon smart pots. 6 plants per 1000w vegged until they have a nice and full canopy.
4 1000's (cant decide between the magnum xxxl's, radiants, or sunsystem 2 reflectors, any input?).
This tent will be a closed environment (sealed) so I could run a 4 burner co2 generator to keep co2 levels at 1500 ppm for flowering. Are grow tents capable of keeping co2 contained efficiently if all zippers are closed?
Each table will have 1 8" inline fan pulling air from outside the tent, through 2 hoods, and exhausting it outdoors. This way I can vent most of the heat generated from the lights without wasting precious co2.
I'm going to be using a portable AC as well as a dehumidifier in the tent. This is were most of my worry lies.
http://www.heartlandamerica.com/browse/item.asp?PIN=99721&SC=WIF10001&
Will this unit (10000btu portable ac / 60 pint per day dehuey) handle the grow tent?
I need to know from somebody whose experienced in using portable ac's to cool multiple lights if a unit like this will be enough to keep temperatures between 78-85 with 4 lights as well as a co2 generator running inside the tent.
I've always aircooled my lights, but they still produce plenty of heat which quickly builds up in a sealed environment. Is a 10k btu ac enough to deal with it?
I'm also curious about the dehuey. It claims 60 pints per day, is this enough for a sealed room in the heart of the flowering cycle? There's gonna be a lot of water in these pots, a lot of air movement too but I realize it can get pretty humid in there. Will I need to buy a more expensive dehumidifier to keep up?
Not really relevant but there will also be a Phresh filter (12") scrubbing constantly either inside the tent or in the room the tent shall be in.
Thanks for the read as well as any feedback you may give, smoke on