So I just converted a garage into a room and got a 4x8x6 grow tent and I have noticed I have had a few problems. I tried reading through a lot of posts but I can't quite figure out what needs to happen next.
1st the setup:
-4x8x6 grow tent with reflective lining
-2 1000W HPS lamps in one cooltube both cooled by a single 6" 440cfm blower into the attic
-the ballasts are in the same room as the tent
-the room is 10x10x8
-my intake ATM (airflow from outside) is 3" ducting to a 4" 144cfm blower to 6" ducting to inside the tent.
the house has an attic and 2 vents to the outside, one in the attic one next to the tent.
2nd The issues:
-temp is steady at about 84 F with the tent open and 2 room fans blowing into the tent. The whole room gets pretty hot too which pretty much kills the idea of intake from the room itself. If i seal the tent the way its setup now the temp rises significantly (90+)and the tent poofs up (im assuming due to lack of exhaust). I think i need some advice on lowering the temp.
-The ins and outs:
How much ins and outs should I install? recommended cfm? do I need 1 fan for in and a seperate for out or can I seal the tent and use one blower as a sucker to suck into/ out of the tent?
In the future:
what is the best way to go about adding co2 later with a tent setup? im worried that if I set up co2 the exhaust will just suck it all out. but if I turn the exhaust off the tent will heat up and the smell will get out.
Any help pointing me in the right direction would be extremely helpful. i can answer questions or add pics of the setup if needed.
1st the setup:
-4x8x6 grow tent with reflective lining
-2 1000W HPS lamps in one cooltube both cooled by a single 6" 440cfm blower into the attic
-the ballasts are in the same room as the tent
-the room is 10x10x8
-my intake ATM (airflow from outside) is 3" ducting to a 4" 144cfm blower to 6" ducting to inside the tent.
the house has an attic and 2 vents to the outside, one in the attic one next to the tent.
2nd The issues:
-temp is steady at about 84 F with the tent open and 2 room fans blowing into the tent. The whole room gets pretty hot too which pretty much kills the idea of intake from the room itself. If i seal the tent the way its setup now the temp rises significantly (90+)and the tent poofs up (im assuming due to lack of exhaust). I think i need some advice on lowering the temp.
-The ins and outs:
How much ins and outs should I install? recommended cfm? do I need 1 fan for in and a seperate for out or can I seal the tent and use one blower as a sucker to suck into/ out of the tent?
In the future:
what is the best way to go about adding co2 later with a tent setup? im worried that if I set up co2 the exhaust will just suck it all out. but if I turn the exhaust off the tent will heat up and the smell will get out.
Any help pointing me in the right direction would be extremely helpful. i can answer questions or add pics of the setup if needed.