when the lights are off couldn't you just set the exhaust fan to run every 2 hours for 15 minutes, and keep your heat set
You should, and a controller.when it comes down to it I'll be the first one to say that I'm scared to run c02. I just don't understand it. Don't you need a regulator?
And i was super fucking scared my first run with it.when it comes down to it I'll be the first one to say that I'm scared to run c02. I just don't understand it. Don't you need a regulator?
I like to encourage people to do it. Night and day difference. Only issue i had was lights out RH at first. Im not to versed on the bottle system, I've just used a burner.I'm running co2 for sure. If I'm going to get 9 gavitas for 4500 dollars I might as well do it right.
Your not gonna like this answer.my room is 18 feet by 18feet would that be overkill?
the mini split that I am getting has a setting to dehudifiyI like to encourage people to do it. Night and day difference. Only issue i had was lights out RH at first. Im not to versed on the bottle system, I've just used a burner.
Your going to need atleast 2 170 pint dehumidifiers. The mini splits will keep everything in check with lights on. But when those lights turn off that humidity shoots up like a rocket.the mini split that I am getting has a setting to dehudifiy
That room is too big for tanks. Unless u live a block from where you refill them.what is making me go with the tank is that I don't want the added heat of the burner
3 humidifiers see thats where the sealed room plan goes to shit. each dehumidifer runs 750 watts plus the 3,000 watt mini split god damnYour going to need atleast 2 170 pint dehumidifiers. The mini splits will keep everything in check with lights on. But when those lights turn off that humidity shoots up like a rocket.
Personally I'd put 4 in their and never worry about it.
Your looking at 15-20gs to setup this room you want properly... Or do it for 6 and never pull the yields your capable of.
so 2 burners and 2 regulators?That room is too big for tanks. Unless u live a block from where you refill them.
2 burners on the opposite side of the room from each other.
You better not run og then....... Although I'm hearing some are killing it at 2-2.5 with the sfv or fire cuts!!!!!!!we are planning on having it set up tax time February. it's me and a partner. so we would have around 20k to cover it. but fuck to invest that much pulling 3 lb a light would be the only way it is worth it cause now I can pull 1 and 3/4 pound a light with no co2 and not running all those dehumidfiers
I run an 8 burner for a slightly bigger space then what you mentioned. If that helps any.so 2 burners and 2 regulators?
one is only enough to cool one room without lights? how do you figure when its 65 degrees outside?Your not gonna like this answer.
You're going to need 2 of those my man. One is enough to barely cool your room with no lights.