Ok song serious about these rails! If I ask questions that have been answered in previous posts forgive me. I am thinking of making the rails modular so they can be easily moved from room to room individually. How do you accomplish the switching from root to veg to flower? Have you had nozzles plug and if yes how is that dealt with? What is the drain tray made from? Is there a noticeable difference in the uninsulated rail? Have you tried running pump continuously? The reason I ask that is my plants seem to do better when doing that. Thanks for any advice SS.
This system is modular, all rails can be easily removed seperately.
I remove the plants from clone and pop into vegger, from vegger to flower I set system up and get res ready then i go get plants from veg room and take them to flower rrorrom and put them in the rails.
I have never worried about clogged sprayers, the system is redundant. My sprayers are in the middle of two plants.
Drain can be made from 2-3" round PVC or fence rails.
There is a difference but I'm waiting til harvest to actually judge it.
I would never run the pump continuously. What a waste oof electricity. Not to mention the heat in the res. I spent a lot of time over many harvests to dial in pump timing.