john073
Well-Known Member
Damn nice, yeah im doing something like that, just using normal pc heatsink and fan should work fine as well.
Damn nice, yeah im doing something like that, just using normal pc heatsink and fan should work fine as well.
is that your setup?That is what those are, that was less than half of the room.... All the fans were running of a PC PSU.
It is a laser cut and bent frame with 3 CPU coolers and a driver on top 3 COBs on bottom.
Those PC fans are very good at transferring the heat to the air, so your air conditioning and insulation game need to be on point for summer.
So i must run them at 48 volts the strips are rated at 48.8v , or is it best to run them lets say at 45v like im doing now at veg stage and 48 or 47.5 at flower stage?
Thanks
Im have them on 40mm wide 5mm thick aluminium flat bar i could get that wide u channel my side, thinking of putting some of the small u channel on the back of the flat bar like 30mm pcs 15 of them on each 1.25m sectic for extra heat conduction.Do these CV drivers only have a voltage poti? If yes, it's okay to dimm the strips via voltage, 45v should anyway the lowest settings, or not? +/- 3v or 45-51v?
There is a correlation between Vf(voltage) and If(current), if you lower the voltage you lower also the current each strip will get. To get the numbers from the datasheet it needs at least 48,8v(@65°C) and if you want to run them harder they need up to 50 or even 51v to reach max. current. The higher the voltage the higher the current flowing thru the strips. You need to look at the datasheet for max. current and set voltage accordingly.
But it's also depending on the case temps. If you mount them on alu c-channels the temps stay a lot lower. The 48,8v are at 65°C, if they run with lets say @50°C voltage would increase by ~0,5v to 49,3v.
Cooler case temps make LED more efficient and allows a higher voltage at the same current. This make water cooling the most efficient way to drive LED's and if you reuse the heat its unbeatable. Can you upload the datasheet here?
Run as close to 48.8 as possible and use the OTHER potentiometer to DIM the lights.So i must run them at 48 volts the strips are rated at 48.8v , or is it best to run them lets say at 45v like im doing now at veg stage and 48 or 47.5 at flower stage?
Thanks
The previous setup, running gen 3 type F now.is that your setup?
Thanks would apreciate the part no, i dont have a build it here at my side just a buildersFor the SA guys tha want to build with 40mm strips, I can give you the Buildit part no. and they can order you the same alu channel from SALBEV.
It is very light weight. If you buy the 8-foot length, there is enough for 2 strips for R200.
What potentiometer should i use do you have an example possibly? Can i get it from buildersRun as close to 48.8 as possible and use the OTHER potentiometer to DIM the lights.
Thanks, what do you use to dimm your lights?I think they all get their aluminium from the same places... Maybe you could phone SALBEV directly...
SALBEV sticker says STEL 2.4 -74x20mmx2.5mm Light duty Bar code 6009600417359
Builders part no 123476 Bar code 2400001234769
Ok thanks, im currently at 45 so i can push it up a bit then thinking of 46 maybe or more but i will try and make the heat a bit better on the aluminiumView attachment 4175418 View attachment 4175419 Trimpots on the drivers.... I run my strips in parallel. at 45.9V.
Im have them on 40mm wide 5mm thick aluminium flat bar i could get that wide u channel my side, thinking of putting some of the small u channel on the back of the flat bar like 30mm pcs 15 of them on each 1.25m sectic for extra heat conduction.
I have 2 of the 3000k strips and 1 of the 4000k strips currently running at 45v the aluminium is not really hot a litlle warm at the back of it front around the strip its cool.
Thank you for the info i will try to get a watt meter from ebay we dont have wallmart this side, south africa here we have import everything lol, yeah the strips can do 48.8v and 3A and the power supply can do 48 but up to 52 i think and 7.3A something like thatFrom what I see on the datasheets the drivers min./max. voltage match almost perfect with the strips min./max. values. Means you can use the build-in voltage poti for dimming. Even if you set max. voltage the strips run below their limits.
It's anyway the only way to dimm the lights with these CV driver so its perfectly fine.
You could use a cheap 10$ wall watt meter like a kill-a-watt to get an idea of how much power is used, Walmart should have them or am4zon/e3ay. At 45v it's probably ¼ - ⅓ of the nominal output.
Someone told met i must not run my meanwells so hard i must only run it at like 60% so basicly 2 strips per 350w meanwell?Yea, that's a max. of 2,43Amps per strip so well within their specs. Meanwells all like to have a bit much juice so maybe 2,5A at 50v or 125w per strip or 375w total if you ramp it up at max..
My power supply is currently in a seperate space then my lights, and lying on a plastic surfice but not getting hot at allNaah, if possible you want to drive them 100% You do want to look at thermal specifications and allow heat to get away from it.. I.e. not screw it to a wooden board or something... There are some details in the datasheet and application notes for most drivers.