If I lose a fan, I'm assuming I'll lose the COB not long after? If a COB drops out wIll the driver adjust current or would you recommend an inline fuse?
.
Could you just sandwich a strip of aluminium plating in between the COB & Heatsink unit (thermal paste in between) so you could have 4 on a strip?
.
How could you connect them for ease of lowering or raising ect? So you only had to use one set of rachet pulleys?
.
Thanks for the help.
(8x $4.60)COB's + (8x $3.49)heatsinks + ($110)driver
=
~$175 ($174.72)
Not bad for a 4'x2' 165-170lm/w build.. Thinking about it..
If you run the COB's at ~40w and a fan fails Tcase would increase to around 70° maybe 80 but thats still within the limits and COBs would'nt be damaged. I've use Vero29gen5 at 1050mA on Arctic Alpines without fans and temps stabilized around 65°C. With gen.7 temps would stay below 60°C.
Build a frame to mount the heatsinks and get a few rope-ratchets as hanging kit(5,60$ e3ay). You could do it like wiete has done it and use alli channels. You can add the fans on the backside of the alli channels.
But you can also use bigger channels and cool them passively. To keep 4 COBs @1050mA cool enough you could use 50x 40x 50mm c-channels in 4ft length. Such a aluminum channel would have ~3100cm² cooling surface and you could make a frame with 4 such alli bars. To keep them cooler and reuse the heat you could add a small fan to the ceiling and let him blow downwards acoss the whole fixture. Such a set-up would be fail safe because it can work completely without fans.
You could use two HLG-320H-C2100B's and use 8 COB's connected in 4s2p(4 in series 2 times in parallel). Would be 300w net., 37,5w per COB and 630-660w at the wall.