Ronin-indi
Well-Known Member
is there an efficiency chart for the cobs at run at different amps somewhere?
Yep, right hereis there an efficiency chart for the cobs at run at different amps somewhere?
mouser is very expensive for cobs, shop around . (kiingbrite, pacificlightconcepts, cutter, octopart)hi everybody!
so I think im gonna order some shtuff for a 4x4' passive... could someone double check my list? Thanks you guys rock!
mouser-
cxb3070 x 12 = 509.04
mwhlg240h-c1050 x 2 =153.28
shipping = 15.00
subtotal=667.32
heatsinkusa-
4.9x42 x 3 = 224.28
shipping/handling = 52.81
subtotal = 277.09
pacificlightconcepts-
bjb 3070 holder x 12 = 30.00
shipping = 12.65
subtotal = 42.65
home depot-
wire, conectors, misc. = 100.00
total = 1097.06
That sucks.well i guess they cancelled it : (
These questions were answered, 3500k is more efficient. Low cri/ highest bin is better.really does was hoping to maybe get clarification on cbx3590 3500k 4000k and their cri comparison info ...and is a hlg-185h-c700b better than the c1400b version. idk what it is (maybe just dumb) but can't figure the chart/graph out. seems the 3590 36v on a driver @700ma are more cost effective than when driven @1.400ma. on the same type/style/# of driver. is this correct?
Every time anyone makes the power savings comparison with HID lighting of any kind, REMEMBER THE HVAC! Add the savings of running your AC half as much or less! Trust me, it makes a big difference in 'power only' payback times!These questions were answered, 3500k is more efficient. Low cri/ highest bin is better.
Everybody needs to answer cost-effective for themselves, but driving at 3590 @700 ma cost more upfront, but seems to have a very quick return if you consider higher yield and quality, and will return even just on the basis of electricity costs eventually.
They usually ship the nest day when I've ordered.Bang did it, 2x 240h-c1050b drivers in the mail.
Tomorrow callin HeatsinkUSA (anybody know the wait time on the 5.88"?)
Next week or two gonna hit up cutter, 12-14 3590s.
Happy Fuckin New Year Er'body!
Lets spend some money!
I personally think that is not the way to think of it i mean i run 3 DE units in 75 Sq feet with no AC only normal ventilation like all grow rooms should have Right ????Every time anyone makes the power savings comparison with HID lighting of any kind, REMEMBER THE HVAC! Add the savings of running your AC half as much or less! Trust me, it makes a big difference in 'power only' payback times!
So REMEMBER THE AC! Because if you don't, that Gavita DE will cook your growroom- and therefore the reverse is also true; in a true apples to apples comparison, AC you aren't using is AC you aren't paying for, and that counts!
and how many cfms of input output air are you using ? even with non air conditioned cooling systems less will be needed compared to equivalent hid systems.I personally think that is not the way to think of it i mean i run 3 DE units in 75 Sq feet with no AC only normal ventilation like all grow rooms should have Right ????
They're dance moves. The 5-step is especially difficult.Can anyone please explain what 2-step, 3-step, 5-step means. especially 3-step.
Im glad you asked, I was just looking into this myself. It seems to be related to the light color and consistency. 1 step would be that all leds in that group would be indistinguishable from one other to the human eye. 2 step would mean that people could distinguish the difference by 1 shade, that is to say 2 shades would be seen. 5 step would be 5 shades of potential difference. In terms of growing, I dont think it would matter. It would be more important for cosmetic reasons. SOURCE.Can anyone please explain what 2-step, 3-step, 5-step means. especially 3-step.