My grow area is 6X12 in a 12X17 room.
I run a undercurrent system with water chiller and window A/C. I run the full Cutting Edge Solutions Nutrient line up.
Love them Love them Love them, best looking plants I've ever grown. Mean and green.
Got a whole house A/C vent in room. Put in 50 amp panel in closet which I robbed from the future hot tub circut. 10 inch exhaust out window above A/C unit. Ph and water temps monitored real time. Electric items are on controller switches. Life is beautiful. I'm in bloom and 3 weeks from harvest. What could go wrong.
My undercurrent I built runs perfect. 120 gallon. 3 fans in room.
So that leaves room temp and humidity. What a nightmare. With door open its not so bad.
3400 watts from 6 lights kick out some serious heat. I think my 5000 btu window a/c doesnt keep up. Gonna try 8000 btu in a few months. I can push 85deg with door closed. Humidity was hitting 75%. Bought a 70 pint Fridgidare dehumidifier. Now I can pull humidity down to 35%. So bumped it up to 45%. Going to 40% for final weeks in 5 days. Thats solved now heat problem. Gotta open door but that rooms loud. Temp goes to 74-78deg. But humidity goes to 35% with dehumidifier off. I think that's too low. Our home humidity is 28% out here on west coast. Then I run humidifier lol its crazy.
So my point is if you are dropping 4000 watts in a 10X10 tent. Tell me how you handle heat and humidity nightmare. Humidity is fine in veg. But when you get in bloom it goes nuts in the room. All those gallons of water they drink everyday have got to go somewhere.
Keep us up to date and good luck. Lol I'm waiting on the electric bill.
View attachment 3647124