Also, I'm finishing up hooking up the rest of my system. Is a check valve needed after the pump? I wasn't sure if it was alright to subject the pump to the constant 125+ psi or if the pump even prevented the backflow since it states it doesn't prevent forward flow even when off. I just thought it easier to ask then hook up the setup and hav eto take some fittings back apart to put in the check valve after testing![]()
The pump will have one but it wont hurt to add another if you want to. There`s only forward flow with the pump off if its being used as line pressure booster (ie for reverse osmosis) where there`s a constant positive pressure on the inlet. Nothing can flow the other way due to the internal non return valve. I use a limited amount of brass and never had any issues, it`s more of a concern with recirculating systems where the concentration can build up in the res. Its not an issue for drain to waste.